Zurn Wilkins 3-375AST 3" RPZ Backflow Preventer | Stainless Body NRS Flanged
Sale!

Zurn Wilkins 3-375AST 3″ RPZ Backflow Preventer | Stainless Body NRS Flanged

Original price was: $4,254.99.Current price is: $298.98.

SKU: 6145325695151 Category:

Description

Zurn Wilkins 3″ 375AST RPZ Backflow Preventer | Stainless Steel, NRS Gate Valves.

Product Overview:

The Zurn Wilkins 3″ 375AST RPZ Backflow Preventer provides superior protection for potable water lines where a health hazard may exist. Built with a durable 304L stainless steel body and non-rising stem (NRS) gate valves, this reduced pressure zone assembly ensures long-lasting performance, ease of maintenance, and full compliance with backflow prevention regulations. Designed for commercial and industrial systems, its short lay length simplifies installation in confined areas.

Features & Benefits:

  • Dual-check with pressure relief zone to prevent backsiphonage and backpressure

  • Compact design ideal for retrofit or space-constrained installs

  • Stainless steel body and NORYL™ internal components for corrosion resistance

  • Lead-free construction meets NSF/ANSI 372 certification

  • Non-rising stem gate valves allow for full flow with minimal space needs

  • Accessible in-line servicing without removing the valve from the pipeline

  • Certified for vertical and horizontal installation

Specifications:

  • Size: 3″

  • Body & Cover: 304L Stainless Steel

  • Check Components: Stainless Steel, NORYL™, EPDM, Buna-N

  • Max Working Pressure: 175 PSI

  • Test Pressure: 350 PSI

  • Operating Temp: up to 140°F

  • End Connections: Grooved (AWWA C606) or Flanged (ANSI B16.1 Class 125)

  • Compliance: ASSE 1013, NSF 61 & 372, FM®, UL®, CSA®, IAPMO®

Installation Tips:

  • Install 12″ to 30″ above grade with proper drainage access

  • Ensure no portion of the assembly is submerged

  • Leave adequate space around the unit for testing and maintenance

  • Follow all local code requirements for backflow prevention assemblies

  • Approved for both vertical and horizontal configurations

FAQs:

Q: What is an RPZ backflow preventer?
A: It’s a reduced pressure zone device with two checks and a relief valve to stop contaminated water from entering the potable system.

Q: Can this be installed outdoors?
A: Yes, with appropriate freeze protection and above-grade placement per code.

Q: Are these valves lead-free?
A: Yes, the assembly is fully certified to NSF/ANSI 372 for use in potable systems.

Q: Can the check assemblies be serviced in-line?
A: Yes, all internal components are accessible without removing the unit.

Reviews

There are no reviews yet.

Be the first to review “Zurn Wilkins 3-375AST 3″ RPZ Backflow Preventer | Stainless Body NRS Flanged”

Your email address will not be published. Required fields are marked *